Description
The Korr Medical Technologies RSS 100 is a complete
spirometry system for use in any application where airway flow and pressure
are measured.
The RSS 100 research spirometry system measures gas
flow using the differential-pressure method. As gas flows through the
pneumotach, the microprocessor-based system converts the measured differential
pressure to volumetric flow rate. Flow and pressure measurements are
used to calculate several ventilator management parameters such as respiratory
rate, lung compliance, tidal volume, minute volume, positive end expiratory
pressure, etc.
The RSS 100 has a graphic liquid-crystal display,
which shows flow, pressure, and volume strip-chart plots as well as
flow-volume and pressure-volume loops. Calculated parameters are also
displayed on the screen. The system can also be interfaced to a computer
through a serial data port. A Windows software program is available
to acquire waveforms and data produced by the RSS 100. Flow, pressure,
volume, and auxiliary pressure signals are available as analog outputs
for convenient and reliable interfacing to a strip chart recorder, oscilloscope,
or other instrument.
Features
- Custom Microsoft Windows software for displaying,
storing, and reviewing data.
- Monitor is fully functional as a stand-alone device.
LCD screen displays waveform and parameter data in real time.
- Embedded microprocessor calculates flow rate and
provides correction for gas density, viscosity, temperature, barometric
pressure, and airway pressure.
- Calculates over 15 ventilatory parameters.
- Integrated breath detection algorithm automatically
detects start and end of breath.
- Custom fixed-orifice, differential pressure pneumotachs
require no user calibration and remain accurate even under extreme
clinical conditions.
- Built-in calibration function for linear "Fleisch"
pneumotachs. Calibration stored in non-volatile memory.
- Serial RS232 and analog outputs provided for simple
computerized data collection.
Calculated Parameters
- Positive End Expiratory Pressure
- Peak Inspiratory Pressure
- Mean Airway Pressure
- Inspiratory Pause Pressure
- Compliance
- Tidal Volume
- Minute Volume
- Respiratory Rate
- Inspiratory and Expiratory Time
- Inspiratory to Expiratory Ratio (I:E)
- Peak Inspiratory and Expiratory Flow Rates
The RSS 100 works with precision molded fixed-orifice
pneumotachs provided with the unit. The proprietary precision molded
pneumotachs do not require any user calibration and are available in
adult and neonatal sizes. These pneumotachs are robust even under extreme
heat and moisture conditions found in critical care conditions. The
RSS 100 is also designed to work with a wide range of linear (Fleisch)
differential pressure pneumotachs.
Note: This device is for research purposes
only, do not base clinical decisions on information obtained from this
device.
Flow (Adult Sensor)
- Range ± 1.0 to 180 LPM
- Accuracy ± 3 % of reading
- Resolution 0.1 LPM
Flow (Neonatal Sensor)
- Range ± 0.24 to 40 LPM
- Accuracy ± 3% of reading
- Resolution 0.01 LPM
Flow (Linear Pneumotachs)
- Linear Pneumotachs (Specifications are sensor dependent)
- Range ± 1000 LPM (MAX)
- Accuracy ± 1% (typical)
Pressure
- Range ± 120 cmH2O
- Accuracy ± 2% of reading
- Resolution 0.2 cmH2O
Power
- Universal Input 90-264 VAC, 47-63 Hz, 3 Watt
Catalog Numbers
- 1000 RSS 100 System
- 2000 RSS 100 Software
- 2100 Neonatal sensor with tubing
- 2101 Adult flow sensor with tubing
- 2102 Adult flow sensor without tubing
- 2200 Adult tubing set
- 3000 RS232 serial cable
Patents
5,535,633; 5,347,843;
5,379,650; Other Patents Pending
|
|